GC Capillary Columns


general purpose columns Polysiloxane Phases with 100% Dimethyl-, 5% Diphenyl- or an increasing share of Cyanopropyl Phenyl groups

Phenylene modified Polysiloxane Phases with minor column bleeding at high maximum temperature

polar Polyethylene Glycol Phases

Capillary Columns for temperature up to 350°C

100% Dimethylpolysiloxane or Phenyl-Polycarboran-Siloxane Phases

 
increasing Polarity
100% Dimethyl Polysiloxane
BP1

non- polar standard column, low bleed
for routine analysis

0.1 - 1.0 µm film thickness -60°C to 340/360°C
1.5 - 3.0 µm film thickness -60°C to 300/320°C
4.0 - 5.0 µm film thickness -60°C to 280/300°C

Column length: 10, 12, 15, 25, 30, 50, 60 m
Column lD: 0.1, 0.15, 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.25, 0.5, 1.0, 2.6, 3.0, 4.0, 5.0 µm

suitable for analysis of hydrocarbons, aromatics, pesticides, phenol, herbicides, amines
SolGel-1ms

robust high temperature non-polar phase for mass spectrometry applications

0.25µm film thickness 0°C to 340/360°C

Column length: 30, 60 m
Column lD: 0.25, 0.32 mm
Film Thickness 0.25 µm

recommended for highly active compounds
BPX1

100% polydimethylsiloxane
non-polar columns, low bleed
for Simulated Distillation in the petroleum industry

0.1 - 0.9 µm film thickness 30°C to 400°C
2.65 µm film thickness 30°C to 370°C

Column length: 6, 10 m
Column lD: 0.1, 0.53 mm
Film Thickness 0.1, 0.9, 2.65 µm

Aluminium Clad: 0.1 µm film thickness 30°C to 430°C

Column length: 5, 10 m
Column lD: 0.53 mm
Film Thickness 0.1, 0.17 µm

ASTM methods D2887 and D6532
BP1 PONA

non-polar phase for PONA analysis

0.5 µm film thickness -60°C to 280/300°C

Column length: 50, 100 m
Column lD: 0.15, 0.25 mm
Film Thickness 0.5 µm

Petroleum hydrocarbons, gasoline range hydrocarbons, MTBE
5% Phenyl Methylpolysiloxane
BP5

non-polar general purpose phase with excellent high temperature characteristics
popular columns used for a wide variety of applications

0.25 - 1.5 µm film thickness -60°C to 320/340°C
> 1.5 µm film thickness-60°C to 280/300°C

Column length: 12, 15, 25, 30, 50, 60 m
Column lD: 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.25, 0.5, 1.0 µm

Aromatics, pesticides, herbicides, drugs of abuse, hydrocarbons, GC/MS applications
5% Phenyl Polysilphenylene-siloxane
BPX5

MS-Premium, low bleed columns with a maximum temperature up to 370°C. Suitable for trace analysis of pesticides, drugs, hydrocarbons and phenols. The BPX5 phase has been designed for robustness and is suitable for over 80% of all routine analyses performed by chromatographers

0.25 - 1.5µm film thickness -40°C to 360/370°C
>1.5µm film thickness -40°C to 350/360°C

Column length: 6, 7, 10, 12, 15, 25, 30, 40, 50, 60 m
Column lD: 0.1, 0.15, 0.18, 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.1, 0.15, 0.18, 0.25, 0.4, 0.5, 1.0, 1.2, 3.0, µm

Comparison of Structure and Retention on various 5 % Phenyl Phases
The advantages of BX5, BX35 and BX50 Phases when analysing aromatic compounds
pdf 1.3 MB
5% Phenyl Polycarboran-siloxane
8% Phenyl Polycarboran-siloxane
HT5

unique high temperature phase suited for simulated distillation and other petroleum applications. This column is the highest temperature column available with a maximum temperature up to 480°C

0.1 - 0.5 µm film thickness 10°C to 380/400°C

Column length: 6, 10, 12, 15, 25, 30 m
Column lD: 0.22, 0.32, 0.53 mm
film thickness 0.1, 0.15, 0.5 µm

Aluminium Clad:
0.1 - 0.5µm film thickness 10°C to 460/480°C

Column length: 5, 6, 12, 25, 50 m
Column lD: 0.22, 0.32, 0.53 mm
Film Thickness 0.075, 0.1, 0.15, µm

simulated distillation, general hydrocarbon profiles, pesticides/herbicides, GC/MS applications
HT8

Unique high temperature phase suited for the analysis of Poly Chlorinated Biphenyl (PCB) congeners. The unique polarity of this phase gives excellent separation of PCB congeners

0.1 - 1.0 µm film thickness -20°C to 360/370°C

Column length: 10, 12, 25, 30, 50, 60 m
Column lD: 0.1, 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.1, 0.22, 0.25, 0.32, 0.53 µm

HT8 Optimized for PCB analysis
specifically designed for the separation of the 209 polychlorinated biphenyl congeners
pdf 635 KB
35% Phenyl Polysilphenylen-siloxane
BPX35

MS-Premium, low bleed columns with a maximum temperature up to 370°C. Especially suited for trace analysis of herbicides and aromatic columns

0.1 - 1 µm film thickness 10°C to 330/360°C

Column length: 10, 15, 25, 30, 50, 60 m
Column lD: 0.1, 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.1, 0.25, 0.5, 1.0 µm

Comparison of Structure and Retention on various 5 % Phenyl Phases
The advantages of BX5, BX35 and BX50 Phases when analysing aromatic compounds
pdf 1.3 MB
BPX608

optimized for ECD. I
i deal for the analysis of organochlorine herbicides and pesticides

0.32 µm film thickness 10° to 360/370°C

Column length: 25 m
Column lD: 0.32 mm
Film Thickness 0.4 µm

environmental analyses, EPA 608, pesticides/herbicides
50% Phenyl Polysilphenylen-siloxane
BPX50

MS-Premium, low bleed columns with a maximum temperature up to 370°C. Suited for a range of EPA methods and pharmaceutical applications

0.1 - 1µm film thickness 80°C to 360/370°C

Column length: 10, 15, 30, 60 m
Column lD: 0.1, 0.25, 0.15, 0.25, 0.32, 0.53mm
Film Thickness 0.05, 0.07, 0.1, 0.15, 0.25, 0.5, 1.0 µm

Comparison of Structure and Retention on various 5 % Phenyl Phases
The advantages of BX5, BX35 and BX50 Phases when analysing aromatic compounds
pdf 1.3 MB
70% Cyanopropyl Polysilphenylene-siloxane
BPX70

MS-Premium, low bleed columns with a maximum temperature up to 260°C. The polarity has been designed for Fatty Acid Methyl ester (FAME) analysis

0.1 - 1.0µm film thickness 50°C to 250/260°C

Column length: 10, 12, 15, 25, 30, 50, 60, 120 m
Column lD: 0.1, 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.2, 0.25, 0.5 µm

Approaches to The Analysis of Saturated and Mono-Unsaturated Fame Using Highly Polar Gc Phases
pdf 1.8 MB
90% Cyanopropyl Polysilphenylene-siloxane
BPX90

MS-Premium, low bleed columns with a maximum temperature up to 280°C. Extremely polar phase for the fast separation of aromatics, perfumes, petrochemicals and other compounds that are difficult to resolve using conventional columns

0.25 - 0.50 µm film thickness 80°C to 280°C

Column length: 15, 30, 60, 100 m
Column lD: 0.25, 0.32 mm
Film Thickness 0.25, 0.5 µm

BPX90 - Analysis of furan fatty acids in Fish
GCMS based structure assignment for furan fatty acids isolated from European Carp
pdf 1.8 MB
Polyethylene Glycol (PEG)
SolGel-WAX

robust, high temperature polar WAX phase. Less susceptible to damage by oxygen than conventional wax columns

0.25 - 1.0 µm film thickness 30°C to 260/280°C

Column length: 10, 15, 30, 60 m
Column lD: 0.1, 0.25, 0.53 mm
Film Thickness 0.25, 0.5 µm

recommended for highly active compounds
BP20 (WAX)

a very polar phase suited to the analysis of alcohols, ketones and aldehydes
also offers excellent separation of aromatic isomers such as the xylene isomers

0.1 - 1.0 µm film thickness 20°C to 260/280°C
> 1.0 µm film thickness 20°C to 240/260°C

Column length: 10, 12, 25, 30, 60 m
Column lD: 0.1,0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.1, 0.25, 0.5, 1.0, 2.0 µm

alcohol, free acids, fatty acid methyl esters, aromatics, solvents, essential oils
Treated Polyethylene Glycol (PEG)
BP21 (FFAP)

a very polar Nitroterephthalic acid modified PEG phase suited to the analysis of free fatty acids

0.25 -0.5 µm film thickness 35°C to 240/250°C

Column length: 12, 15, 25, 30, 50, 60 m
Column lD: 0.25, 0.32, 0.53 mm
Film Thickness 0.25, 0.5, 1.0 µm

volatile free acids, fatty acid methyl esters, alcohols, aldehydes, acrylates, ketones
14% Cyanoproylphenyl Polysiloxane
BP10 (1701)

this low bleed and highly inert phase has been selected with a polarity suited for the separation of organochlorine pesticides listed in the EPA 608 and 8081 methods

0.25 - 1µm film thickness -20°C to 280/300°C

Column length: 12, 15, 25, 30, 50, 60 m
Column lD: 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.25, 0.5, 1.0 µm

Environmental analyses (EPA methods 608 and 8081), pesticides/herbicides, drugs of abuse, pharmaceuticals
50% Cyanopropylphenyl Polysiloxan
BP225

mid to high polarity L
low bleed B
bonded and cross-linked phase

0.1 - 1.0 µm film thickness 40°C to 230/250°C

Column length: 25, 50 m
Column lD: 0.22, 0.32, 0.53 mm
Film Thickness 0.25, 0.5 µm

Fatty Acid Methyl Esters (FAMEs), carbohydrates, neutral sterols
Cyanopropylphenyl Polysiloxane (Volatiles)
BPX-VOLATILES

a polar phase used for EPA volatile organics analysis (EPA 624, SW-846 8240/8260), alcohol analysis and for USP G43

1.0 - 3.0µm film thickness 0°C to 290/300°C

Column length: 20, 30, 40, 60 m
Column lD: 0.18, 0.25, 0.32, 0.53 mm
Film Thickness 1.0, 1.4, 1.8, 3.0 µm

Environmental analyses, volatile organics, alcohol analysis, USP G43
BP624

US EPA 624 optimized column
designed for volatiles analysis
ideal for EPA624, SW-846 and 8240/8260 methods
ideal for USP G43 method

1.0 - 3.0µm film thickness 0°C to 230/240°C

Column length: 15, 25, 30, 50, 60 m
Column lD: 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 1.2, 1.4, 1.8, 3.0 µm

EPA method 624, drinking water volatiles, chlorinated hydrocarbons, solvents
Permethylated Beta Cyclodextrin (Chiral)
CYDEX-B

Chiral columns for the separation of enantiomeric compounds found in natural products

30°C to 220/240°C

Column length: 25, 50 m
Column lD: 0.22, 0.32 mm
Film Thickness 0.25 µm

Separation of enantiomeric compounds found in natural products
GC Supplies
GC Capillary Columns
GC Syringes
GC Septa
Ferrules
Injector Liner
 

SGE Application Guide
pdf 3.3 MB


SGE Catalogue
pdf 27.7 MB

© infochroma ag, Sumpfstr. 3, CH-6300 Zug; Tel: +41 41 748 50 60, info@infochroma.ch last Update 18.08.2011